● MVB redundant interface, supporting ESD +, EMD interface
● Compliance with IEC61375 standard
● Two 10/100M Ethernet, optionally supporting TRDP protocol
● X3 extended interface: Optional RS-232, RS-422 or RS-485
● X4 extended interface: Optional RS-422, RS-485 or CAN bus
● Perfect isolation protection
● Industrial wide temperature
1. Introduction
The Yacer MVB-TCMS TCN protocol converter provides MVB interface, two 100M Ethernet interfaces and two extended interfaces to implement protocol conversion between MVB, serial port, CAN bus and Ethernet, and optionally supports TRDP protocol.
Industrial wide temperature, complete isolation and protection, compact size, suitable for train communication network.
2. Applications
● Protocol conversion between MVB and Ethernet interface;
● Protocol conversion between MVB and Serial interface;
● Protocol conversion between Serial and Ethernet interface;
● Protocol conversion between CAN and Ethernet interface;
● Protocol conversion between TRDP and UDP;
● Protocol conversion between TRDP and Serial interface;
● Train Communication Network (TCN);
● Train Control and Management System (TCMS);
● Embedded development and application.
3. Features
● MVB redundant interface, supporting ESD+, EMD interface;
● Compliance with IEC61375 standard;
● Two 10/100M Ethernet interfaces, optionally supporting TRDP protocol;
● X3 extended interface: Optional RS-232, RS-422 or RS-485 serial port;
● X4 extended interface: Optional RS-422, RS-485 serial port or CAN bus;
● Perfect isolation protection;
● Industrial wide temperature.
4. Function Blocks
The basic function blocks are shown in the following figure:
● X20, X21 are MVB dual line redundant interfaces S1;
● X3 is the expansion interface S3, optionally RS-232, RS-422 or RS-485;
● X4 is the expansion interface S4, optionally CAN, RS-422 or RS-485;
● ETH1, ETH2 are two 100M Ethernet ports, which are connected to connectors X10 and X11 respectively;
● X5 is the power connector.
Item |
Parameters |
Details |
S1 MVB Interface |
Connector |
1 x male D-Sub 9 (X20) + 1 x female D-Sub 9 (X21) |
Media type |
Optional EMD, ESD+ |
|
Device Class |
Class 1 |
|
Device Capabilities |
Device_Status, Process_Data |
|
Number of PD ports |
1024 |
|
Isolation |
2.5 kVrms |
|
S3 Extended Interface |
Connector |
1 x male D-Sub 9 (X3) |
Interface type (three-choice) |
RS-232 full-duplex serial RS-422 full-duplex isolated serial RS-485 half-duplex isolated serial |
|
Baud rate |
Asynchronous ≤ 1 Mbps |
|
Isolation |
2.5 kVrms |
|
S4 Extended Interface |
Connector |
1 x male D-Sub 9 (X4) |
Interface type (three-choice) |
CAN bus isolation interface (CAN2.0A, CAN2.0B, ISO 11898) RS-422 full-duplex isolated serial RS-485 half-duplex isolated serial |
|
Baud rate |
UART ≤ 1 Mbps CAN: 50 Kbps ~ 1 Mbps |
|
Isolation |
2.5 kVrms |
|
Ethernet Interface |
Connector |
2 x M12 with D-coding |
Function |
Ethernet switching, dual-IP function |
|
Rate |
10/100 Mbps adaptive, Forced 100 Mbps |
|
Protocol |
TCP/IP, optionally supporting TRDP |
|
Programming interface |
UDP Server, UDP Client Unicast/Multicast/Broadcast |
|
Isolation |
1.5 kVrms |
|
Configuration Management |
Configuration tool |
yacer-DMS configuration management software |
Configuration interface |
Ethernet Interface, optional serial port |
|
Power Requirements |
Power Supply |
LV: Nominal 24V, tolerance 9 ~ 36VDC MV: Nominal 36V, 48V, tolerance 18 ~ 75VDC HV: Nominal 72V, 96V, 110V, tolerance 40 ~ 160VDC |
Isolation protection |
>1.5 kV, Anti-reverse protection |
|
Power consumption |
< 3 W |
|
Connector |
3 pin connector with 5mm pitch (Phoenix Contact MSTB 2,5 / 3-GF or equivalent) |
|
Mechanical Characteristics |
Dimensions |
H x W x D: 124 mm x 36 mm x 104 mm |
Weight |
500g |
|
Operating Environment |
Operating temperature |
-40 ~ +70℃ |
Storage temperature |
-40 ~ +85℃ |
|
Operating humidity |
5 ~ 95% RH (no condensation) |
Icon |
Function |
Tools and software |